SUNNY CENTRAL STRING-MONITOR US
The U.S. insurance for even better solar yields
Detailed panel monitoring: the Sunny Central String-Monitor US. By measuring and comparing the individual string currents, power deviations in the solar array are detected reliably and are analyzed directly in the Sunny Central. For the measurement of the string currents, there are three variants of string fuse protection, all of which comply with the NEC standard, making the Sunny Central String-Monitor well suited for use in the U.S. solar market.
Efficient
- Optimum fault recognition for high yields
- Reduced system costs through use of up to nine devices per Sunny Central inverter
Precise
- System monitoring as with Sunny Boy via string current monitoring
- DC distributor box with NEMA 3R with integrated current measurement
Flexible
- Three separate constructions for the best possible system design
- Optionally suitable for use near to the coast
Straightforward
- Convenient mounting preparation due to removable floor and side plates
- Simple configuration of the string current monitoring
| PV generator connection | Sunny Central String-Monitor US Version 24 | Sunny Central String-Monitor US Version 32 | Sunny Central String-Monitor US Version 64 |
| Input voltage range | 0 ... 600 V DC | 0 ... 600 V DC | 0 ... 600 V DC |
| Max fuse size (10 x 38 class CC fuses) | 20 A, 600 V DC 1) | 15 A, 600 V DC 1) | 8 A, 600 V DC 1) |
| Max. PV short-circuit current per string | 12.8 A 2) | 9.6 A 2) | 5.1 A 2) |
| Max. number of strings | 24 | 32 | 64 |
| Fused inputs per measuring channel | 3 | 4 | 8 |
| PV array configuration | neg. or pos. grounded | neg. or pos. grounded | neg. or pos. grounded |
| Number of measuring channels | 8 | 8 | 8 |
| Sunny Central Connection | |||
| DC short-circuit current | 480 A | 480 A | 512 A |
| Max. operating output current, A DC, continuous | 308 A | 308 A | 328 A |
| Max. number of cables per output port | 2 | 2 | 2 |
| Mechanical Data | |||
| Dimensions: W x H x D in inches | 31.5 x 31.5 x 9.8 | 31.5 x 31.5 x 9.8 | 31.5 x 47.2 x 11.8 |
| Weight | 143 lbs | 146 lbs | 194 lbs |
| Protection rating | NEMA 3R | NEMA 3R | NEMA 3R |
| Housing material | Steel or Aluminum | Steel or Aluminum | Steel or Aluminum |
| Ambient conditions | |||
| Permissible ambient temperatures | –13 °F to 113 °F | –13 °F to 113 °F | –13 °F to 113 °F |
| Rel. humidity | up to 95%, condensation possible |
up to 95%, condensation possible |
up to 95%, condensation possible |
| Communication | |||
| Connection SSM-US | RS485 | RS485 | RS485 |
| Type designation | SSM-US | SSM-US | SSM-US |
| 1) These values indicate input current without the derating factor of NEC articles 690.8(A)(1) and 690.8 (8)(1) applied. | |||
| 2) These values indicate input current with the derating factor of NEC articles 690.8(A)(1) and 690.8 (8)(1) applied. |
Downloads
Language:
Data sheet
|
240 KB |
SUNNY CENTRAL STRING-MONITOR US - Accurate monitoring for large North American systems ensures high yields Type: Data sheet Language: English (US) Document number: SUNNYSTRINGU-DUS100716 Version number: 1.6 |
Technical information
|
803 KB |
SUNNY CENTRAL STRING-MONITOR US - Accessories for all Sunny Central inverters on the North American market Type: Technical information Language: English (US) Document number: SSM-UUS094511 Version number: 1.1 |
Technical Description
|
2.699 KB |
SUNNY CENTRAL STRING-MONITOR US - Technical Description Type: Technical Description Language: English (US) Document number: SSMUS-TUS094511 Version number: 1.1 |
|
325 KB |
SUNNY CENTRAL STRING-MONITOR US - Preparation for Installation Type: Technical Description Language: English (US) Document number: SSMUS_Aus-TUS094310 Version number: 1.0 |

SMA Feed