Turnkey
- Modular power solution allows for rapid field deployment
- Conversion, distribution and control functions included
- Customizable service options
Innovative
- Based on award-winning SMA Sunny Central technology
- Leading grid management functions available
Secure
- Renowned SMA manufacturing standards ensure long term operation
- Diverse service options address project-specific needs
Flexible
- Available as an open platform, with a canopy shade or as a full steel enclosure
- Can be installed on a concrete slab, piers or vault
| SAMPLE CONFIGURATIONS | ||||
| MVPP 1.0 MW |
MVPP 1.0 MW |
MVPP 1.5 MW |
MVPP 1.6 MW |
|
| Technical data | 600 V DC | 1000 V DC | 1000 V DC | 1000 V DC |
| Input (DC) | ||||
| Max. DC power | 1013 kW | 1120 kW | 1796 kW | 1796 kW |
| MPP voltage range (@77°F/122°F at 60Hz) |
330 V…600 V / 330 V…600 V a) | 449 V…820 V / 436 V…820 V a) | 609 V…820 V / 554 V…820 V a) | 641 V…820 V / 583 V…820 V a) |
| Rated input voltage | 380 V | 480 V | 595 V | 620 V |
| Max. DC voltage | 600 V | 1000V / 1100 V b) | 1000V / 1100 V b) | 1000V / 1100 V b) |
| Max. DC input current | 3200 A | 2500 A | 2800 A | 2800 A |
| Number of independent MPP inputs | 2 | 2 | 2 | 2 |
| Number of fused DC inputs | 18 | 18 / 64 (Optiprotect) | 18 / 64 (Optiprotect) | 18 / 64 (Optiprotect) |
| Output (AC) | ||||
| Nominal AC power | 1000 kVA @113 °F | 1000 kVA @122 °F | 1500 kVA @122 °F | 1600 kVA @122 °F |
| Maximum AC power | 1000 kVA @113 °F | 1100 kVA @77 °F | 1650 kVA @77 °F | 1760 kVA @77 °F |
| Nominal AC voltage options | 12.47 kV;13.8 kV 20.6 kV;24.9 kV 27.6 kV;34.5 kV |
12.47 kV;13.8 kV 20.6 kV;24.9 kV 27.6 kV;34.5 kV |
12.47 kV;13.8 kV 20.6 kV;24.9 kV 27.6 kV;34.5 kV |
12.47 kV;13.8 kV 20.6 kV;24.9 kV 27.6 kV;34.5 kV |
| Total Harmonic Distortion of grid current | < 3 % @ nominal power | < 3 % @ nominal power | < 3 % @ nominal power | < 3 % @ nominal power |
| Grid frequency | 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| Power factor (adjustable) | 0.90 lead - 0.90 lag | 0.90 lead - 0.90 lag | 0.90 lead - 0.90 lag | 0.90 lead - 0.90 lag |
| Transformer vector group | Dy1y1 | Dy1y1 | Dy1y1 | Dy1y1 |
| Transformer no load taps | ±2.5% & ±5% | ±2.5% & ±5% | ±2.5% & ±5% | -5%; -2.5%; +3.5%; +7.0%; +10.5%; +14% c) |
| Transformer cooling type | KNAN | KNAN | KNAN | KNAN |
| Power consumption | ||||
| Internal consumption in operation (inverter + MV-transformer) | < 3400 VA + < 12 kVA | < 3000 VA + < 12 kVA | < 3000 VA + < 19.2 kVA | < 3000 VA + < 19.2 kVA |
| Standby consumption (inverter + MV-transformer) | < 220 VA + < 1500 VA | < 200 VA + < 1500VA | < 200 VA + < 2200 VA | < 200 VA + < 2200 VA |
| Supply via internal PV power /external power supply / green power | opt. / opt. / yes | opt. / opt. / yes | opt. / opt. / yes | opt. / opt. / yes |
| External auxiliary supply voltage | 208 V; 480 V; 600 V | 208 V; 480 V; 600 V | 208 V; 480 V; 600 V | 208 V; 480 V; 600 V |
| Efficiency | ||||
| Max. efficiency / European efficiency / CEC efficiency inverter | 98.60% / 97.90% / 98.00% | 98.60% / 98.40% / 98.50% | 98.60% / 98.40% / 98.50% | 98.60% / 98.40% / 98.50% |
| Protection rating and ambient conditions | ||||
| Protection rating | NEMA 3R | NEMA 3R | NEMA 3R | NEMA 3R |
| Operation temperature range @ nominal power | -13 °F ... +113 °F | -4°F ... +122°F | -4°F ... +122°F | -4°F ... +122°F |
| Storage temperature standard / low temperature option | -13°F ... +140°F / -40°F ... +140°F | -4°F ... +140°F / -40°F ... +140°F | -4°F ... +140°F / -40°F ... +140°F | -4°F ... +140°F / -40°F ... +140°F |
| Relative humidity | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % |
| Snow load (psf) | >40 | >40 | >40 | >40 |
| Wind load (mph) | >110 | >110 | >110 | >110 |
| Fresh air consumption (CFM) | 3531.6 | 3531.6 | 3531.6 | 3531.6 |
| Max. altitude above sea level (m) | 2000 | 2000 | 2000 | 2000 |
| Design lifetime (years) | >20 | >20 | >20 | >20 |
| Compliance and certificates | ||||
| Seismic rating according UBC sec. 1632 and IBC sec. 1613d) | Site class D; Ss =2.0g; S1=1.0g | Site class D; Ss =2.0g; S1=1.0g | Site class D; Ss =2.0g; S1=1.0g | Site class D; Ss =2.0g; S1=1.0g |
| NEC 2011 / OSHA 1910 | yes / yes | yes / yes | yes / yes | yes / yes |
| PE certificate on mechanical; electrical; seismic for California / other state | yes / opt. | yes / opt. | yes / opt. | yes / opt. |
| Features | ||||
| Disconnect Unit | opt. | opt. | opt. | opt. |
| AC circuit breakers located in inverter / Disconnect Unit | yes / opt. | yes / opt. | yes / opt. | yes / opt. |
| Project specific power supply for tracker motors etc. | opt. | opt. | opt. | opt. |
| Auxiliary power fusible disconnect switch / overvoltage protection | yes / opt. | yes / opt. | yes / opt. | yes / opt. |
| Customer SCADA system compartment e) | 34” x 30” x 12”; Supply: 120V/60Hz/max 250W | 34” x 30” x 12”; Supply: 120V/60Hz/max 250W | 34” x 30” x 12”; Supply: 120V/60Hz/max 250W | 34” x 30” x 12”; Supply: 120V/60Hz/max 250W |
| On platform | 2x 120V/ max. 250W each | 2x 120V/ max. 250W each | 2x 120V/ max. 250W each | 2x 120V/ max. 250W each |
| Transformer alarm contacts: Thermo / Pressure / Fluid level | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. | yes / opt. / opt. |
| Transformer oil containment | opt. | opt. | opt. | opt. |
| Delivery FCA/on site | yes / opt. | yes / opt. | yes / opt. | yes / opt. |
| Platform design | ||||
| Open including Disconnect Units | ||||
| Width / Height / Depth | 29’ / 8’9” / 12’ | 29’ / 8’9” / 12’ | 29’ / 8’9” / 12’ | 29’ / 8’9” / 12’ |
| Weight (lb) | <39.000 | <39.000 | <39.000 | <39.000 |
| Open excluding Disconnect Units | ||||
| Width / Height / Depth | 24’ / 8’9” / 12’ | 24’ / 8’9” / 12’ | 24’ / 8’9” / 12’ | 24’ / 8’9” / 12’ |
| Weight (lb) | <34.000 | <34.000 | <34.000 | <34.000 |
| Canopy including Disconnect Units | ||||
| Width / Height / Depth (roof) | 31’ / 10’6” / 14’ | 31’ / 10’6” / 14’ | 31’ / 10’6” / 14’ | 31’ / 10’6” / 14’ |
| Weight (lb) | <42.000 | <42.000 | <42.000 | <42.000 |
| Canopy excluding Disconnect Units | ||||
| Width / Height / Depth (roof) | 26’ / 10’6” / 14’ | 26’ / 10’6” / 14’ | 26’ / 10’6” / 14’ | 26’ / 10’6” / 14’ |
| Weight (lb) | <37.000 | <37.000 | <37.000 | <37.000 |
| Enclosure including Disconnect Units | ||||
| Width / Height / Depth | 32’ / 10’6” / 12’ | 32’ / 10’6” / 12’ | 32’ / 10’6” / 12’ | 32’ / 10’6” / 12’ |
| Weight (lb) | <48.000 | <48.000 | <48.000 | <48.000 |
| Enclosure excluding Disconnect Units | ||||
| Width / Height / Depth | 27’ / 10’6” / 12’ | 27’ / 10’6” / 12’ | 27’ / 10’6” / 12’ | 27’ / 10’6” / 12’ |
| Weight (lb) | <43.000 | <43.000 | <43.000 | <43.000 |
| yes=Standard features no=Optional features |
||||
| Type Designation | MV-1000HE-US | MV-1000CP-10 | MV-1500CP-10 | MV-1600CP-10 |
| a) @ 1.05 UACnom and cos ϕ = 1 b) Standard: 1000 V DC optional 1100 V DC with a start-up < 1000 V DC c) Reduction from 1600 kVA to 1400 kVA in 40 kVA steps possible to balance module degradation d) Pier height 3 ft max. mounting via wedge anchors included in delivery e) Suitable to -13 °F ... +140 °F has to include buffer module |
||||
Downloads
Language:
Data sheet
|
568 KB |
MV POWER PLATFORM 1.0 / 1.25 / 1.4 / 1.5 / 1.6 MW - Modular utility-scale power solution Type: Data sheet Language: English (US) Document number: MVPP-DUS113620 Version number: 2.0 |