Economical
- Optimal failure detection for high yields
- Reduced system costs though use of up to nine devices per Sunny Central
Precise
- Failure detection through string current monitoring
- DC distributor box in NEMA 3R with integrated current measurement
Flexible
- Three different versions for the best possible system design
- Optionally suitable for installation near the coast
User-friendly
- Convenient installation preparation due to detachable side and base plates
- Simple configuration of the string current monitoring
| Sunny Central String-Monitor-US 24 | Sunny Central String-Monitor-US 32 | Sunny Central String-Monitor-US 64 | |
| PV generator connection | |||
| Input voltage range | 0 ... 600 V DC | 0 ... 600 V DC | 0 ... 600 V DC |
| Max. PV short-circuit current per string | 12.8 A 1) | 9.6 A 1) | 5.1 A 1) |
| Max. fuse size (10 x 38 class CC fuses) | 20 A, 600 V DC 2) | 15 A, 600 V DC 2) | 8 A, 600 V DC 2) |
| Max. number of strings | 24 | 32 | 64 |
| Fused inputs per measuring channel | 3 | 4 | 8 |
| PV array confi guration | neg. or pos. grounded | neg. or pos. grounded | neg. or pos. grounded |
| Number of measuring channels | 8 | 8 | 8 |
| Sunny Central Connection | |||
| DC short-circuit current | 480 A | 480 A | 512 A |
| Max. continuous DC current | 308 A | 308 A | 328 A |
| Max. number of cables per output | 2 | 2 | 2 |
| Mechanical data | |||
| Dimensions (H x W x D) in mm (in) | 800 / 800 / 250 (31.5 / 31.5 / 10) |
800 / 800 / 250 (31.5 / 31.5 / 10) |
800 / 1200 / 300 (31.5 / 47 / 12) |
| Weight | 65 kg (143 lb) | 65 kg (143 lb) | 88 kg (194 lb) |
| protection rating | NEMA 3R | NEMA 3R | NEMA 3R |
| Enclosure materials | steel or stainless steel | steel or stainless steel | Steel or stainless steel |
| Ambient conditions | |||
| Operating temperature range | –25 °C ... +45 °C (–13 °F ... +113 °F) |
–25 °C ... +45 °C (–13 °F ... +113 °F) |
–25 °C ... +45 °C (–13 °F ... +113 °F) |
| Rel. humidity | up to 95%, (condensation allowed) | up to 95%, (condensation allowed) | up to 95%, (condensation allowed) |
| Communication | |||
| SSM-U connection | RS485 | RS485 | RS485 |
| Certifi cates / listings | |||
| Certifi cates | UL 1741 | UL 1741 | UL 1741 |
| Type designation | SSM-US | SSM-US | SSM-US |
Downloads
Language:
Data sheet
|
260 KB |
SUNNY CENTRAL STRING-MONITOR-US - Insurance for solar yields in North America Type: Data sheet Language: English (US) Document number: SUNNYSTRINGUS-DUS103817 Version number: 1.7 |
Technical information
|
803 KB |
SUNNY CENTRAL STRING-MONITOR US - Accessories for all Sunny Central inverters on the North American market Type: Technical information Language: English (US) Document number: SSM-UUS094511 Version number: 1.1 |
Technical Description
|
2.699 KB |
SUNNY CENTRAL STRING-MONITOR US - Technical Description Type: Technical Description Language: English (US) Document number: SSMUS-TUS094511 Version number: 1.1 |
|
325 KB |
SUNNY CENTRAL STRING-MONITOR US - Preparation for Installation Type: Technical Description Language: English (US) Document number: SSMUS_Aus-TUS094310 Version number: 1.0 |
Catalog
|
9.850 KB |
SUNNY FAMILY 2011/2012 - The Future of Solar Technology Type: Catalog Language: English (US) Document number: SFK_KUS113710 Version number: 1.0 |

SMA Feed