| Technical Data | Windy Boy Protection Box 400 |
Windy Boy Protection Box 500 |
Windy Boy Protection Box 600 |
| General information | |||
| Suitable for | WB 1200, WB 1700 | WB 3300, WB 3800, WB 3600TL, WB 5000TL | WB 2500, WB 3000, WB 5000A, WB 6000A |
| Rectifier | Integrated | Integrated | Integrated |
| Dimensions (W / H / D ) | 280 / 220 / 130 mm | 280 / 220 / 130 mm | 280 / 220 / 130 mm |
| Weight | 5 kg | 5 kg | 5 kg |
| PV array connection | |||
| Quantity | 1 x three-phase | 1 x three-phase | 1 x three-phase |
| AC voltage | 3 x 0 V – 500 V | 3 x 0 V – 500 V | 3 x 0 V – 500 V |
| AC current | 3 x 0 A – 11.5 A | 3 x 0 A – 11.5 A | 3 x 0 A – 11.5 A |
| Array frequency | 0 Hz – 400 Hz | 0 Hz – 400 Hz | 0 Hz – 400 Hz |
| Nominal power | 1 kW – 3 kW | 3 kW – 5 kW | 2 kW – 7 kW |
| Windy Boy connection | |||
| Quantity | 3 | 3 | 3 |
| Voltage limitation (DC) | 400 V | 500 V | 600 V |
| Total power | 3 kW | 5 kW | 7 kW |
| Load resistance connection | |||
| Quantity | 1 | 1 | 1 |
| Nominal voltage (DC) | 400 V | 500 V | 600 V |
| Continuous power | 3 | 5 | 7 |
| Efficiency | |||
| Max. efficiency | > 99.95 % | > 99.95 % | > 99.95 % |
| Conduction losses at continuous power | 15 W | 20 W | 30 W |
| General data | |||
| Ambient temperature | -25 °C ... +60 °C | -25 °C ... +60 °C | -25 °C ... +60 °C |
| Degree of protection (according to IEC 60529) | IP54 | IP54 | IP54 |
| Accessories | |||
| Load resistance | opt. | opt. | opt. |
| Type designation | WBP-Box 400-11 | WBP-Box 500-11 | WBP-Box 600-11 |