SUNNY CENTRAL 500CP-US 600V

SUNNY CENTRAL 500CP-US 600V

Cost-optimized solution for commercial and utility-scale projects

The Sunny Central CP-US series delivers outstanding performance. In combination with an external transformer, the Sunny Central CP-US can be connected to commercial building power or any utility grid. The UL listed CP-US also supports grid stability through leading grid management functions including Low Voltage Ride Through. Both the outdoor enclosure featuring OptiCool™ active temperature management and a separate connection area ensure simple installation while maximizing returns. With peak efficiency greater than 98 percent, it outperforms all other inverters in its class. The Sunny Central CP-US can also be integrated with the Power Plant Controller as well as the Medium-Voltage Power Platform for utility-scale applications.

Economical

  • Outdoor enclosure allows for direct field deployment
  • Small footprint and light weight for easy shipping and installation

Efficient

  • Highest efficiency in its power class
  • Full nominal power at ambient temperatures up to 50 °C

Flexible

  • Integrated AC disconnect for NEC 2011 compliance
  • Optional DC disconnects

Reliable

  • Easy and safe installation with large, separate connection area
  • Powerful grid management functions (incl. LVRT)
  • Full UL 1741 and IEEE 1547 compliance

Show All / Hide All SUNNY CENTRAL 500CP-US 600V
Input (DC)
Max. DC power (@ cos ϕ = 1) 560 kW 1
Max. DC voltage 600 V
MPP voltage range (@ 25 °C at 60Hz) 550 kW / 363 – 480 Vdc
MPP voltage range (@ 50 °C at 60Hz) 500 kW / 330 – 480 Vdc
Rated input voltage 360 V
Max. input current 1600 A
Min. input voltage / VMPPmin at IMPP < lDCmin 330 V
Number of independent MPP inputs 1
Number of DC inputs: busbar / fuses Busbar / 6–9
Output (AC)
Nominal AC power 500 kVA @ 50 °C (122 °F)
Intermediate AC power 530 kVA @ 35 °C (95 °F)
Maximum AC power 550 kVA @ 25 °C (77 °F)
Max. AC current 1588 A
Nominal AC current 1444 A
AC grid frequency 60 Hz
AC voltage range 180 V – 220 V
AC voltage range, full active power 196 V – 210 V
Power factor (adjustable) 1 / 0.8 leading ... 0.8 lagging
THD < 5 %
Efficiency 2
Max. efficiency > 98.1 %
CEC efficiency 3 > 97.5 %
Ambient Conditions
Operating temperature range -25 °C ... +50 °C (-13 °F ... +122 °F)
Max. temperature for nominal conditions +50 °C (+122 °F)
Protection rating NEMA 3R
Installation indoors / outdoors yes / yes
Relative humidity 15 % ... 95 %
Fresh air consumption 3000m³/h
Internal consumption at nominal power < 1800 W
Standby consumption (Pnight) < 150 W 4
General data
Dimensions (W / H / D) 2562 / 2272 / 956mm (101 / 90 / 38 inch)
Weight < 1870 kg (4123 lb)
Grid monitoring yes
Ground-fault monitoring / remote-ground fault monitoring opt. / opt.
Insulation monitoring opt.
Surge arrester for auxiliary power supply yes
Cooling concept OptiCool
Degree of protection: electronics / connection area / degree of protection according to IEC 60721-3-4 NEMA 3R / NEMA 3R / 4C2, 4S2
Application In unprotected outdoor environments
Certificates / Listings
Certificates, approvals and compliants UL 1741, UL 1998, IEEE 1547
EMC conformity FCC, Part 15, Class A
Features
DC connection Ring terminal lug
AC connection Ring terminal lug
HMI touchscreen HMI touch display
Communication / protocols Ethernet (optical fiber optional), Modbus
Auxiliary power supply via external 208 V / external 400 V / external 480 V / integrated green power opt. / opt. / opt. / opt.
SC-COM yes
Color of enclosure, door, base, roof RAL 9016 / 9016 / 7004 / 7004
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.
Type designation
Type designation SC 500CP-US-10 600V
Footnote
1) Specifications apply to irradiation values under STC
2) Measured without internal voltage supply at VDC = 330 V
3) Measured efficiency includes all auxiliary power
4) By external 400 V auxiliary power supply
Language

Data sheet

SUNNY CENTRAL 500CP-US 600V - Cost-optimized solution for commercial and utility-scale projects SC500CPUS_600V-DUS131724W.pdf
  • Type: Data sheet
  • Language: English (US)
  • Number: SC500CPUS_600V-DUS131724
  • Version: 2.4

Technical Description

SC-COM Modbus® Interface - Technical Description SC-COM-MODBUS-TB-US-en-20.pdf
  • Type: Technical Description
  • Language: English (US)
  • Number: SC-COM-MODBUS-TB-US-EN-20
  • Version: 2.0

Operating Instructions

Installation Guide

Certificate

Buy American Act of 1933 - Qualification Letter BAA Qualification Letter 02042014.pdf
  • Type: Certificate
  • Language: English (US)
  • Number: BAA Qualification Letter 02042014
  • Version: 1.4

Maintenance Manual

Maintenance protocol

Maintenance Report - SUNNY CENTRAL 500CP-US/CA / 500CP-US/CA 600V / 630CP-US/CA / 720CP-US/CA / 750CP-US/CA / 800CP-US/CA SCCP-US-WP-US_en-30.pdf
  • Type: Maintenance protocol
  • Language: English (US)
  • Number: SCCP-US-WP-US_en-30
  • Version: 3.0

Contact

SMA America, LLC
6020 West Oaks Blvd, Ste 300
Rocklin, CA 95765 U.S.A.

Tel. +1 916 625 0870
Fax +1 916 625 0871
Toll Free 1-888-4SMAUSA

www.SMA-America.com
Service Line phone number (Toll free):

+1 877-697-6283
+1 877-MY-SMATech
Service@SMA-America.com