Unmatched performance for utility-scale PV

With its extended features, the new Sunny Central CP XT series maximizes both energy production and project investment returns through innovative technology and an extensive suite of integrated grid management functions. The Sunny Central CP XT is also optimized for cold temperatures down to -40 °C and provides full nominal power in continuous operation up to 50 °C (40°C for Sunny Central 1000CP XT). The Sunny Central CP XT can also be integrated with the SMA Power Plant Controller.

Economical

  • Up to 1 MW power class
  • Significant savings in balance of system components due to 1,000 V operating voltage
  • Outdoor enclosure simplifies deployment


Efficient

  • Highest efficiency in its class
  • Full nominal power at ambient temperatures up to 50 °C (40°C for Sunny Central 1000CP XT)
  • 10% additional power for continuous operation at ambient temperatures up to 25 °C


Flexible

  • Wide DC input voltage for flexible use of various module configurations
  • Optional extended input range up to 1,100 V
  • Optional DC disconnects


Versatile

  • Powerful grid management functions (incl. LVRT and Frequency Ride
    Through)
  • Optimized for extreme climate conditions including -40 °C to 62 °C


Assembled in the USA

  • Compliant with ARRA "Buy American" clause

Contact

SMA America, LLC
6020 West Oaks Blvd, Ste 300
Rocklin, CA 95765 U.S.A.

Tel. +1 916 625 0870
Fax +1 916 625 0871
Toll Free 1-888-4SMAUSA

www.SMA-America.com
Service Line phone number (Toll free):

+1 877-697-6283
+1 877-MY-SMATech
Service@SMA-America.com

Our Service Line team is available to provide competent advice Monday to Friday from 6:00 a.m. to 5:00 p.m. Pacific time.

Sunny String-Monitor SSM / SSM16-11 / SSM24-11

Detailed plant control: the Sunny String-Monitor watches over the PV array by measuring and comparing individual string currents. This allows certain detection of reductions in performance, which can be directly analyzed via Sunny Central Control. Delivered in an enclosure for wall installation (IP 65).

SMA String Combiner

Sunny Main Box Cabinet

 

Disconnect Unit

Contact

SMA America, LLC
6020 West Oaks Blvd, Ste 300
Rocklin, CA 95765 U.S.A.

Tel. +1 916 625 0870
Fax +1 916 625 0871
Toll Free 1-888-4SMAUSA

www.SMA-America.com
Service Line phone number (Toll free):

+1 877-697-6283
+1 877-MY-SMATech
Service@SMA-America.com

Our Service Line team is available to provide competent advice Monday to Friday from 6:00 a.m. to 5:00 p.m. Pacific time.

Language

Operating Instructions

Operating Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850 CP XT / 900 CP XT SCCP-BE-D4btf-US-en-22.pdf
  • Type: Operating Instructions
  • Language: English (US)
  • Number: SCCP-BE-D4btf-US-en-22
  • Version: 2.2

Installation Guide

Disconnect Unit for SUNNY CENTRAL 250U/500U/500HE‑US and SUNNY CENTRAL CP - Unpacking DISU_SCUS-AP-eng-IUS110911.pdf
  • Type: Installation Guide
  • Language: English (US)
  • Number: DISU_SCUS-AP-eng-IUS110911
  • Version: 1.1
Disconnect Unit for Sunny Central 250U/500U/500HE-US/CA and Sunny Central CP - Installation Guide DISU_SCUS-IA-IUS111711.pdf
  • Type: Installation Guide
  • Language: English (US)
  • Number: DISU_SCUS-IA-IUS111711
  • Version: 1.1
SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT - Installation Manual SCCPXT-IA-D4btf-US-en-22.pdf
  • Type: Installation Guide
  • Language: English (US)
  • Number: SCCPXT-IA-D4btf-US-en-22
  • Version: 2.2
SERVICE TENT - Installation Guide SCxxxCPZelt-eng-IUS103910.pdf
  • Type: Installation Guide
  • Language: English (US)
  • Number: SCxxxCPZelt-eng-IUS103910
  • Version: 1.0

Brochure

SMA SERVICE FOR PV POWER PLANTS - Successful Projects with Sunny Central System Solutions SERVICE-SC-KEN1609.pdf
  • Type: Brochure
  • Language: International
  • Number: SERVICE-SC-KEN1609
  • Version: 3.1

Certificate

Type Certificate - BDEW for SUNNY CENTRAL CP (XT) ZE_BDEW_SCxxxxCPXT_en_61.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_SCxxxxCPXT_en_61
  • Version: 6.1
Factory Inspection Certificate for Made in European Union SUNNY BOY / SUNNY ISLAND / SUNNY TRIPOWER / SUNNY CENTRAL ZE_Made-in-EU_SB-STP-SC_en_12.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_Made-in-EU_SB-STP-SC_en_12
  • Version: 1.2

Technical information

Technical Information - Plant Communication in Large-Scale PV Power Plants and Rules for Network Planning SC-PO-TI-en-33.pdf
  • Type: Technical information
  • Language: International
  • Number: SC-PO-TI-en-33
  • Version: 3.3

Warranty

SMA Warranty - SUNNY CENTRAL SC-ZE-GEBED-US_en-10.pdf
  • Type: Warranty
  • Language: English (US)
  • Number: SC-ZE-GEBED-US_en-10
  • Version: 1.0
INVOICE FORM - THE SMA SERVICE REBATE FOR QUALIFIED ELECTRICAL PROFESSIONALS INVOICEFORM_SERVICEREBATE-en-16.pdf
  • Type: Warranty
  • Language: International
  • Number: INVOICEFORM_SERVICEREBATE-en-16
  • Version: 1.6

Manufacturers Declaration

Buy American Act of 1933 - Qualification Letter BAA Qualification Letter 02042014.pdf
  • Type: Manufacturers Declaration
  • Language: English (US)
  • Number: BAA Qualification Letter 02042014
  • Version: 1.4
Manufacturer’s Certification Statemant SMAManufactCert9Dec2014.pdf
  • Type: Manufacturers Declaration
  • Language: English (US)
  • Number: SMAManufactCert9Dec2014
  • Version:
Manufacturer's Declaration - Static MPPT Efficiency of 99.8% with OptiTrac ZE-HK-MPPT-SB-STP-SC-en-13.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE-HK-MPPT-SB-STP-SC-en-13
  • Version: 1.3

Contact

SMA America, LLC
6020 West Oaks Blvd, Ste 300
Rocklin, CA 95765 U.S.A.

Tel. +1 916 625 0870
Fax +1 916 625 0871
Toll Free 1-888-4SMAUSA

www.SMA-America.com
Service Line phone number (Toll free):

+1 877-697-6283
+1 877-MY-SMATech
Service@SMA-America.com

Our Service Line team is available to provide competent advice Monday to Friday from 6:00 a.m. to 5:00 p.m. Pacific time.

SMA. Your partner for large-scale PV plants

As the leader in technology and the world market, we offer our customers technology and expertise for PV power plants in the megawatt range.

More information »

References

Learn more about the flexible uses of our products by seeing how they are used at selected reference plants.

To the references »